Service Flow
Building Approval and Certificate of Proper Function Information
The legal basis, service flow and requirements for PBG and SLF applications, and the building inspection flow.

Legal Basis for PBG and SLF Implementation
Applicants submit building permit applications through an online system or directly to the licensing service office. This process involves collecting required documents such as building plans, Building Construction Permit (IMB), and other supporting documents.
- Law Number 28 of 2002 on Buildings
- Law Number 11 of 2010 on Cultural Heritage
- Law Number 6 of 2023 on the Stipulation of Government Regulation in Lieu of Law Number 2 of 2022 on Job Creation into Law
Building Approval (PBG)
Building Approval, abbreviated as PBG, is a permit granted to building owners to construct new buildings, modify, expand, reduce, and/or maintain buildings in accordance with building technical standards.
Technical planning documents are submitted to the Regency/City Government to obtain PBG before construction implementation.

Open and register on the simbg.pu.go.id(opens in a new tab) website
The completeness of the files is checked by the Technical Service verifier
Technical Consultation Meeting by TPA/TPT
Letter of compliance with technical standards by the head of the technical service, and determination of levies
SKRD Delivery, Retribution Payment and PBG Issuance
General Document Requirements for Building Approval (PBG)
Land Data
- Land Certificate
- Land Use Permit
- Land and Building Tax Payment Proof
- Land Boundary Map
- Soil Test Results
General Data
- Identity Card/Residence Permit Information
- Spatial Information (ITR/KRK/KKPR)
- Land Use Permit
- Environmental Documents
- Service Provider Data and Work Contract
Architecture Data
- Architectural Drawings
- Architectural Technical Specifications
Structural Data
- Structural Analysis
- Structural Drawings
- Structural Technical Specifications
MEP Data
- MEP Analysis and Calculations
- Electrical System Drawings
- Lightning Protection System Drawings
- Data and Communication System Drawings
- Security System Drawings
- Plumbing Sanitation System Drawings
- Fire Protection System Drawings
- HVAC System Drawings
- MEP Technical Specifications
Certificate of Proper Function (SLF)
The Building Certificate of Proper Function, abbreviated as SLF, is a certificate issued by the Regional Government to declare the feasibility of building functionality before it can be utilized.

Open and register on the simbg.pu.go.id(opens in a new tab) website
The completeness of the files is checked by the Technical Service verifier
Technical Consultation Meeting by TPA/TPT
Letter of compliance with technical standards by the head of the technical service
Retribution calculation
Issuance of SLF
General Document Requirements for Certificate of Proper Function (SLF)
Land Data
- Land Certificate
- Land Use Permit
- Land and Building Tax Payment Proof
General Data
- Identity Card/Residence Permit Information
- Spatial Information (ITR/KRK/KKPR)
- Land Use Permit
- Environmental Documents
- Planning Service Provider Data
- SLF (If already owned)
- PBG (If already owned)
Architecture Data
- As-built Architectural Drawings
- Architectural Technical Specifications
Structural Data
- Structural Analysis
- As-built Structural Drawings
- Structural Technical Specifications
Building Technical Data
- Functionality Feasibility Report
- As-built Drawings (Architecture-Structure-MEP)
- Technical Review Data and Work Contract
PBG / SLF Inspection Flow
The assessment process by the inspector is a crucial stage in ensuring that a building complies with the Building Approval (PBG) and Certificate of Feasibility (SLF). After the PBG decree is issued, the inspector is assigned by the supervisor to conduct an inspection. The construction schedule is determined, and the inspection is carried out according to the established schedule. The inspection results are then evaluated to determine whether the building meets the required standards.
If the inspection results indicate compliance, the final documents are uploaded as the last step before issuing the SLF decree. However, if discrepancies are found, the PBG may be frozen. Once all requirements are met, an SLF issuance notification is sent, and the SLF decree is delivered by the Technical Departments before being printed.
This process ensures that every building receiving an SLF has undergone a thorough verification process and complies with the applicable regulations.

PBG Decree Issued
Inspector Assigned by Supervisor
Add Construction Schedule
Waiting for Inspection Schedule
Inspection Conducted by Inspector
Inspection Results
The inspection result decides what comes next:
Upload Final Documents
SLF Notification Issued
SLF Decree Delivered by Technical Department
Print SLF Decree
PBG Document On Hold